Advanced Battery Chamber Next

Charge-discharge tests of automotive secondary batteries have problems of being unable to perform accurate evaluation and having differences in environment temperature due to high heating of the battery during high input-output characteristic measurement and increased heat generation caused by battery degradation during long cycle and life testing.

In addition, when charge-discharge testing several batteries installed in the test area at the same time, deviations in temperature uniformity and heat generation of a battery to be cause of changes in the heat history of the batteries, thereby hindering correct evaluation. In an effort to solve these problems, ESPEC applied its long-cultivated environment control technology to develop the Advanced Battery Chamber Next (precision temperature control chamber) with multi-area temperature control.

Specifications & Features:

Category Item Specifications and features
Performance Temperature range -40°C to +100°C
Temperature uniformity ±0.5°C (deviation from temperature setting for central air temperature (total 6 points) for each battery installation area)
Allowable heat load 500 W (at -20°C with air temperature control)
Dimensions Inside dimensions
(W × H × D mm)
800 × 790 × 525 (excluding protrusions)
Outside dimensions
(W × H × D mm)
1000 × 2196 × 1255 (including protrusions)
Safety Devices Pressure release vent φ100mm
Options Specimen temperature control Applicable temperature range: -20°C to +60°C
Allowable heat load: Supports number of specimens and usage temperature range
Relay module Supports no-wiring inside of test area with test chamber rear pass-through method (Standard: φ 100 cable port × 3)
CO2 fire extinguisher Automatically extinguishes fire after detecting heat or smoke at thermal runaway and stops operation, linkable to intake/exhaust damper
Smoke detector Uses optical spot detector for efficient detection of smoke during thermal runaway
CO/H2 gas detector Pump suction type that collects gas generated from battery, 2-stage alert, linkable to intake/exhaust damper
Intake/exhaust damper Supports forced ventilation of gas inside of the chamber after CO2 fire extinguisher spray, interlock to gas detector

Features: 

  • Strong support of enhanced reproducibility and accuracy for cycle characteristics and life evaluation testing
  • Strong support of enhanced reproducibility and accuracy for temperature characteristics testing and constant current load characteristics testing
  • Multi-area temperature control
  • Change in battery temperature due to charge-discharge and the effects of individual specimen temperature control
  • Conventional test chamber
  • Multi-area control (3areas)
  • Specimen temperature control (3cells)